Measure the resistance between pin 1 of the EGR Delta P Sensor and ground.
If the resistance is greater than 3Ω, go to step 6
.
If the resistance is less than 3Ω, repair the short circuit between pin 1 of the EGR Delta P Sensor harness connector and ground. Refer to "39.3.1.1 Verify Repairs"
.
Measure the resistance between pin 3 of the EGR Delta P Sensor and ground.
If the resistance is greater than 3Ω, repeat steps 3
through 6
. If the results are the same, call the Detroit Diesel Customer Support Center (313–592–5800).
If the resistance is less than 3Ω, repair the short circuit between pin 3 of the EGR Delta P Sensor harness connector and ground. Refer to "39.3.1.1 Verify Repairs"
.
Section 39.3.1.1 Verify Repairs
Verify repairs as follows:
Turn ignition OFF.
Reconnect any electrical connections that were disconnected to perform the diagnosis.
Clear codes with DDDL 7.0 or latest version.
Start and bring engine up to operating temperature (over 140°F/60°C).
Verify operation is satisfactory and no warning lamps illuminate. If warning lamps illuminate, troubleshoot the codes. If assistance is required, call the Detroit Diesel Customer Support Center at 313–592–5800.
EPA07 Series 60 DDEC VI Troubleshooting Guide - 6SE567