Figure 1. Idle Validation Switch, Part of the Accelerator Pedal Assembly
Disconnect the CPC #1 connector.
Measure the resistance between pin 4 of the Idle Validation Switch connector and ground.
If the resistance is less than 5 Ω, repair the short to ground between pin 6 of the CPC #1 connector and pin 4 of the Idle Validation Switch connector. Refer to "44.3.1.1 Verify Repairs"
.
If the resistance is greater than 5 Ω, go to step 4
.
Measure the resistance between pin 5 of the Idle Validation Switch connector and ground.
If the resistance is less than 5 Ω, repair the short to ground between pin 3 of the CPC #1 connector and pin 5 of the Idle Validation Switch connector. Refer to "44.3.1.1 Verify Repairs"
.
Reconnect any electrical connections that were disconnected to perform the diagnosis.
Clear codes with DDDL 7.0 or latest version.
Start and bring engine up to operating temperature (over 140°F/60°C).
Verify operation is satisfactory and no warning lamps illuminate. If warning lamps illuminate, troubleshoot the codes. If assistance is required, call the Detroit Diesel Customer Support Center at 313–592–5800.
EPA07 Series 60 DDEC VI Troubleshooting Guide - 6SE567