Measure the resistance across pins 1 and 2 of the CMP harness connector.
If the resistance is less than 5 Ω, repair short between pins 1 and 2 of the CMP harness connector and the pins 44 and 45 of the MCM 120 pin connector. Refer to "77.1.1.1 Verify Repairs"
.
If the resistance is greater than 5 Ω, go to step 5
.
Measure the resistance between pin 1 of the CMP harness connector and pin 44 of the MCM 120 pin connector
If the resistance is greater then 5 ohms, repair open between pin 1 of the CMP harness connector and pin 44 of the MCM 120 pin connector. Refer to "77.1.1.1 Verify Repairs"
.
Measure the resistance between pin 2 of the CMP harness connector and pin 45 of the MCM 120 pin connector.
If the resistance is greater then 5 ohms, repair open between pin 2 of the CMP harness connector and pin 45 of the MCM 120 pin connector. Refer to "77.1.1.1 Verify Repairs"
.
If the resistance is less than 5 Ω, review steps 2
through 6
. If the results are the same, contact the Detroit Diesel Customer Support Center (313–592–5800).
Section 77.1.1.1 Verify Repairs
Verify repairs as follows:
Turn ignition OFF.
Reconnect any electrical connections that were disconnected to perform the diagnosis.
Clear codes with DDDL 7.0 or latest version.
Start and bring engine up to operating temperature (over 140°F/60°C).
Verify operation is satisfactory and no warning lamps illuminate. If warning lamps illuminate, troubleshoot the codes. If assistance is required, call the Detroit Diesel Customer Support Center at 313–592–5800.
EPA07 Series 60 DDEC VI Troubleshooting Guide - 6SE567