Note: This failure is only monitored when the engine is in smoke control mode.
Section 92.1.1 EGR High Flow Check
Check as follows:
Turn the ignition ON (key ON, engine OFF).
Using DDDL 7.X, perform the Turbo Hysteresis test.
If the Turbo Hysteresis test fails, refer to "6.5 Turbocharger (Diesel)"
in the EPA07 Series 60 Workshop Manual
(DDC-SVC-MAN-0005) for turbo diagnostics.
If the Turbo Hysteresis test passes, go to step 3
.
Check EGR valve operation. Command PWM1 to 50% while monitoring "EGR Actual Position." Does "EGR Actual Position" read between 48-52%?
If no issues are found with intake air system, obtain DDDL log file of failure and contact the Detroit Diesel Customer Support Center (313–592–5800) for further instruction.
Section 92.1.1.1 Verify Repairs
Verify repairs as follows:
Turn ignition OFF.
Reconnect any electrical connections that were disconnected to perform the diagnosis.
Clear codes with DDDL 7.0 or latest version.
Start and bring engine up to operating temperature (over 140°F/60°C).
Verify operation is satisfactory and no warning lamps illuminate. If warning lamps illuminate, troubleshoot the codes. If assistance is required, call the Detroit Diesel Customer Support Center at 313–592–5800.
EPA07 Series 60 DDEC VI Troubleshooting Guide - 6SE567