This code is typically EGR Low Flow (System Restriction Detected).
Section 92.4.1 EGR Low Flow Restriction Check
Check as follows:
Turn the ignition ON (key ON, engine OFF).
Using DDDL 7.X, perform Turbo Hysteresis test.
If the Turbo Hysteresis test fails, refer to the refer to "6.5 Turbocharger (Diesel)"
in the EPA07 Series 60 Workshop Manual
(DDC-SVC-MAN-0005) for turbo diagnostics.
Check the Inlet Manifold Pressure Sensor; using DDDL 7.X compare inlet manifold pressure to barometric pressure. Is the inlet manifold pressure within 0.6 psi of barometric pressure?
If voltage is not within the range above, inspect electrical connections upstream to the MCM (sensor, ATD harness 10–pin, 31–pin VIH and the 120–pin MCM) for corrosion spread pins. If connector damage is found repair as necessary. If no corrosion or damage is found replace the suspect sensor. Refer to "92.4.1.1 Verify Repairs"
.
Start the engine.
Increase engine to 1500 rpm while monitoring DPF Inlet Pressure.
Inspect DOC Inlet face for soot contamination, or “DOC Push Out,” also inspect DPF Outlet for soot contamination. Replace contaminated/damaged component(s), re-install and perform parked regeneration.
Turn the engine OFF.
Remove the EGR valve and inspect the butterfly for physical damage.
Reconnect any electrical connections that were disconnected to perform the diagnosis.
Clear codes with DDDL 7.0 or latest version.
Start and bring engine up to operating temperature (over 140°F/60°C).
Verify operation is satisfactory and no warning lamps illuminate. If warning lamps illuminate, troubleshoot the codes. If assistance is required, call the Detroit Diesel Customer Support Center at 313–592–5800.