Measure the voltage between pins 1 of the AP harness connector and ground.
If the voltage is between 4.5 and 5.5 volts, repair the open circuit between pin 3 of the AP harness connector and pin 4 of the CPC #1 connector. Refer to "109.2.1.1 Verify Repairs"
.
If the voltage is less than 4.5, repair the open circuit between pin 1 of the AP harness connector and pin 8 of the CPC #1 connector. Refer to "109.2.1.1 Verify Repairs"
.
Turn the ignition OFF.
Disconnect the CPC #1 connector.
Measure the resistance between pin 2 of the AP harness connector and pin 7 of the CPC #1 connector.
Reconnect any electrical connections that were disconnected to perform the diagnosis.
Clear codes with DDDL 7.0 or latest version.
Start and bring engine up to operating temperature (over 140°F/60°C).
Verify operation is satisfactory and no warning lamps illuminate. If warning lamps illuminate, troubleshoot the codes. If assistance is required, call the Detroit Diesel Customer Support Center at 313–592–5800.
EPA07 Series 60 DDEC VI Troubleshooting Guide - 6SE567