Measure the voltage between pins 1 and 3 of the IMP Sensor harness connector.
If the voltage is between 4.5 and 5.5 volts, go to step 7
.
If the voltage is less than 4.5 volts, go to step 6
.
Measure the voltage between pin 3 of the IMP Sensor harness connector and ground.
If the voltage is between 4.5 and 5.5 volts, repair the open circuit between pin 1 of the IMP Sensor harness connector and pin 105 of the 120–pin MCM connector. Refer to "112.4.1.1 Verify Repairs"
.
If the voltage is less than 4.5 volts, repair the open circuit between pin 3 of the IMP Sensor harness connector and pin 82 of the 120–pin MCM connector. Refer to "112.4.1.1 Verify Repairs"
.
Turn the ignition OFF.
Disconnect the 120–pin MCM connector.
Measure the resistance between pins 1 and 3 of the IMP Sensor harness connector.
If the resistance is less than 5 Ω, repair the short between pin 82 of the 120–pin MCM connector and ground. Refer to "112.4.1.1 Verify Repairs"
.
Measure the resistance between pin 2 of the IMP Sensor harness connector and ground.
If the resistance is greater than 5 Ω, repair the open circuit between pin 2 of the IMP Sensor harness connector and pin 54 of the 120–pin MCM connector. Refer to "112.4.1.1 Verify Repairs"
.
Reconnect any electrical connections that were disconnected to perform the diagnosis.
Clear codes with DDDL 7.0 or latest version.
Start and bring engine up to operating temperature (over 140°F/60°C).
Verify operation is satisfactory and no warning lamps illuminate. If warning lamps illuminate, troubleshoot the codes. If assistance is required, call the Detroit Diesel Customer Support Center at 313–592–5800.