Measure the resistance between pin 62 of the MCM 120–pin connector and ground.
If the resistance is less than 5 Ω, repair the short to ground between pin 62 of the MCM 120–pin connector and the front injector valve cover connector, EGR Valve, Fuel Cutoff Valve and or Electronic Dosing Valve. Refer to "126.1.1.1 Verify Repairs"
.
Measure the resistance between pin 64 of the MCM 120–pin connector and ground.
If the resistance is less than 5 Ω, repair the short to ground between pin 64 of the MCM 120–pin connector and the front injector valve cover connector, EGR Valve, Fuel Cutoff Valve and or Electronic Dosing Valve. Refer to "126.1.1.1 Verify Repairs"
.
If the resistance is greater than 5 Ω, contact the Detroit Diesel Customer Support Center at 313–592–5800 for MCM replacement.
Section 126.1.1.1 Verify Repairs
Verify repairs as follows:
Turn ignition OFF.
Reconnect any electrical connections that were disconnected to perform the diagnosis.
Clear codes with DDDL 7.0 or latest version.
Start and bring engine up to operating temperature (over 140°F/60°C).
Verify operation is satisfactory and no warning lamps illuminate. If warning lamps illuminate, troubleshoot the codes. If assistance is required, call the Detroit Diesel Customer Support Center at 313–592–5800.
EPA07 Series 60 DDEC VI Troubleshooting Guide - 6SE567